Package | nictiz.fhir.nl.stu3.zib2015 |
Type | StructureDefinition |
Id | Id |
FHIR Version | R3 |
Source | https://simplifier.net/resolve?scope=nictiz.fhir.nl.stu3.zib2015@1.0.0&canonical=http://nictiz.nl/fhir/StructureDefinition/zib-AdministrationSchedule |
Url | http://nictiz.nl/fhir/StructureDefinition/zib-AdministrationSchedule |
Version | 1.0 |
Status | retired |
Date | 2016-12-12T16:58:13.365+00:00 |
Name | ZIB-Administration-Schedule |
Title | HCIM Administration Schedule |
Experimental | False |
Realm | nl |
Authority | hl7 |
Description | The frequency indicates the number of dose moments per time unit, usually per day. If this frequency is included, then the Interval will not have been included. Usually, frequency comprises both amount and time unit (3 times a day), but it can occur without the time unit (single use). In that case, a reasonable distribution over the day is expected, but exact times are not given. This is left to the patient. It is the most common manner of extramural prescription. In the case of Baxter packs and intramural care, such a prescription is used to draw up a (location-specific) outline for distribution times (logistics). The time unit of the frequency must be the same as how it is indicated in the textual description of the dose. Example: for a '2x a day...' dose: amount = 2 time unit = 'day'. for a '3x a week...' dose: amount = 3 time unit = 'week'. |
Copyright | CC0 |
Type | Timing |
Kind | primitive-type |
StructureDefinition | |
http://nictiz.nl/fhir/StructureDefinition/zib-InstructionsForUse ![]() | HCIM InstructionsForUse |
No resources found
{
"resourceType" : "StructureDefinition",
"id" : "zib-AdministrationSchedule",
"meta" : {
"versionId" : "5",
"lastUpdated" : "2017-10-26T14:41:16.5+02:00"
},
"url" : "http://nictiz.nl/fhir/StructureDefinition/zib-AdministrationSchedule",
"version" : "1.0",
"name" : "ZIB-Administration-Schedule",
"title" : "HCIM Administration Schedule",
"status" : "retired",
"date" : "2016-12-12T16:58:13.365+00:00",
"publisher" : "Nictiz",
"contact" : [
{
"name" : "Nictiz",
"telecom" : [
{
"system" : "email",
"value" : "info@nictiz.nl",
"use" : "work"
}
]
}
],
"description" : "The frequency indicates the number of dose moments per time unit, usually per day. If this frequency is included, then the Interval will not have been included. Usually, frequency comprises both amount and time unit (3 times a day), but it can occur without the time unit (single use). In that case, a reasonable distribution over the day is expected, but exact times are not given. This is left to the patient. It is the most common manner of extramural prescription. In the case of Baxter packs and intramural care, such a prescription is used to draw up a (location-specific) outline for distribution times (logistics). The time unit of the frequency must be the same as how it is indicated in the textual description of the dose. Example: for a '2x a day...' dose: amount = 2 time unit = 'day'. for a '3x a week...' dose: amount = 3 time unit = 'week'.",
"copyright" : "CC0",
"fhirVersion" : "3.0.1",
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"uri" : "https://zibs.nl/wiki/InstructionsForUse-v1.0(2017EN)",
"name" : "HCIM InstructionsForUse-v1.0(2017EN)"
},
{
"identity" : "hcim-range-v1.0-2017EN",
"uri" : "https://zibs.nl/wiki/Range-v1.0(2017EN)",
"name" : "HCIM Part Range-v1.0(2017EN)"
}
],
"kind" : "primitive-type",
"abstract" : false,
"type" : "Timing",
"baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Timing",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "Timing",
"path" : "Timing",
"short" : "AdministeringSchedule",
"definition" : "Specifications of the times at which the medication is to be administered. This is indicated as follows: \r\nTime(s) (16:00) or indications (âbefore mealsâ) at which the medication is to be taken each day.\r\nA specific number of times the medication is to be taken each day (\"3x a day\"), indicated with the frequency\r\nA time interval between consecutive doses (âEvery 2 hoursâ, âevery 3 daysâ), indicated with the word Interval.\r\nCombined periods with an interval and duration (â1 daily for three out of four weeks: the pill scheduleâ)\r\n\r\n\r\nIf a certain medication is not to be taken daily, the aforementioned can be combined with daily indications: \r\nOne or more week days on which the medication is to be administered (e.g. âMonday, Wednesday, Fridayâ)\r\nâ3x a weekâ, â2x a monthâ.\r\n\r\n\r\nThe specified administration âinfiniteâ is automatically to be repeated until: \r\nThe end date and time has been reached\r\nThe total administration duration has been reached (14 days)\r\n\r\n\r\nA specific amount of administrations has been reached (â20 dosesâ, âone-time onlyâ), to be entered in the NumberOfDoses concept.",
"alias" : [
"Toedieningsschema"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.19948"
}
]
},
{
"id" : "Timing.event",
"path" : "Timing.event",
"short" : "AdministrationTime",
"definition" : "The time of administration is a specific time of day (on the clock). This time usually isnât (intended to be) exact. There can be multiple administering times in one day. \r\n \r\nThe ideal time of administration can also be entered as a time of day (morning, afternoon, evening, night-time). The administration time is then to be left empty, and the time of day can be entered in the TimeOfDay concept",
"alias" : [
"Toedientijd"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.19951"
}
]
},
{
"id" : "Timing.repeat.bounds[x]",
"path" : "Timing.repeat.bounds[x]",
"short" : "DoseDuration",
"definition" : "The intended time duration for these dosing instructions.",
"alias" : [
"Doseerduur"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.22506"
}
]
},
{
"id" : "Timing.repeat.duration",
"path" : "Timing.repeat.duration",
"short" : "Duration of administration",
"definition" : "Defines the amount of time during which medication is being administered. This is used especially in the context of administering liquids.",
"alias" : [
"toedieninsgduur"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.23141"
}
]
},
{
"id" : "Timing.repeat.frequency",
"path" : "Timing.repeat.frequency",
"short" : "Frequency",
"definition" : "The frequency indicates the number of dose moments per time unit, usually per day. If this frequency is included, then the Interval will not have been included. Usually, frequency comprises both amount and time unit (3 times a day), but it can occur without the time unit (single use). In that case, a reasonable distribution over the day is expected, but exact times are not given. This is left to the patient. It is the most common manner of extramural prescription. In the case of Baxter packs and intramural care, such a prescription is used to draw up a (location-specific) outline for distribution times (logistics). The time unit of the frequency must be the same as how it is indicated in the textual description of the dose. Example: for a '2x a day...' dose: amount = 2 time unit = 'day'. for a '3x a week...' dose: amount = 3 time unit = 'week'.",
"alias" : [
"frequentie",
"frequentie vaste waarde",
"frequentie min"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.19949"
}
]
},
{
"id" : "Timing.repeat.frequencyMax",
"path" : "Timing.repeat.frequencyMax",
"short" : "maximumValue",
"definition" : "If present, indicates that the frequency is a range - so to repeat between [frequency (min)] and [frequencyMax] times within the period or period range.",
"alias" : [
"maximumWaarde"
],
"mapping" : [
{
"identity" : "hcim-range-v1.0-2017EN",
"map" : "NL-CM:20.1.3"
}
]
},
{
"id" : "Timing.repeat.period",
"path" : "Timing.repeat.period",
"short" : "Interval",
"definition" : "Interval indicates the time between dose times. If this is included, then the <i>Frequency </i>will not have been included. \r\n \r\nExamples: every 4 hours, every 3 weeks. \r\n\r\nThe times can now be chosen freely, but distribution throughout the day is more precise, and the interval between times is important (e.g. in the case of antibiotics) \r\nIn the case of Baxter packs and intramural care, such a prescription is used to draw up a (location-specific) outline for distribution times (logistics)",
"alias" : [
"Interval"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.19950"
}
]
},
{
"id" : "Timing.repeat.dayOfWeek",
"path" : "Timing.repeat.dayOfWeek",
"short" : "WeekDay",
"definition" : "WeekDay indicates a pattern of doses on fixed week days.",
"alias" : [
"Weekdagen"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.19952"
}
]
},
{
"id" : "Timing.repeat.timeOfDay",
"path" : "Timing.repeat.timeOfDay",
"short" : "AdministrationTime",
"definition" : "The time of administration is a specific time of day (on the clock). This time usually isnât (intended to be) exact. There can be multiple administering times in one day. The ideal time of administration can also be entered as a time of day (morning, afternoon, evening, night-time). The administration time is then to be left empty, and the time of day can be entered in the TimeOfDay concept.",
"alias" : [
"Toedientijd"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.19951"
}
]
},
{
"id" : "Timing.repeat.when",
"path" : "Timing.repeat.when",
"short" : "TimeOfDay",
"definition" : "Time of day: morning, afternoon, evening, night.",
"comment" : "Time of day: morning, afternoon, evening, night. A ConceptMap (http://nictiz.nl/fhir/ConceptMap/DagdeelCodelijst-to-EventTiming) is available that maps TimeOfDayCodelist to the EventTiming valueset.",
"alias" : [
"Dagdeel"
],
"mapping" : [
{
"identity" : "hcim-instructionsforuse-v1.0-2017EN",
"map" : "NL-CM:9.12.19953"
}
]
}
]
},
"text" : {
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.